Product Identification

Product ID:AV-2018A, NICKEL-CADMIUM SEALED CELL BATTERY
MSDS Date:02/19/1999
FSC:6140
NIIN:01-343-1594
MSDS Number: BNWYD

Responsible Party
AVEX ELECTRONICS CORPORATION
1683 WINCHESTER ROAD
BENSALEM, PA 19020
US

Emergency Phone: 215-638-1515

Info Phone: 215-638-1515

Cage: 58414

Contractor
AVEX ELECTRONICS CORP
1026 BENSALEM, PA 19020-4510 US

Telephone: 215-638-1515

Cage: 58414

Ingredients

NICKEL (PRESENT AS THE METAL, NICKEL HYDROXIDE, NICKEL

CAS: 7440-02-0

RTECS: QR5950000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192


CADMIUM (PRESENT AS THE METAL, CADMIUM HYDROXIDE, CADMIUM

CAS: 7440-43-9

RTECS: EU9800000

OSHA PEL 0.1MG/M3FUME;0.2DUST

ACGIH TLV: 0.05 MG/M3 DUST;9192

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE: INHALATION OF CADMIUM DUST MAY
CAUSE IRRITATION, COUGHING,CHEST PAIN,SWEATING,CHILLS,SHORTNESS OF
BREATH AND WEAKNESS. NICKEL MAY CAUSE LOCAL DERMATITIS. INGESTION
OF EITHER MAY CAUSE NAUSEA,VO MITING,DIARRHEA. CHRONIC: LONG TERM
EXPOSURE MAY CAUSE EMPHYSEMS, KIDNEY DISFUNCTION, AND/OR BONE
LESIONS, LUNG CANCER.
Explanation of Carcinogenicity:NICKEL AND CADMIUM AND THEIR COMPOUNDS
ARE LISTED AS CARCINOGENS OR POTENTIAL CARCINOGENS BY NTP, IARC,
OSHA.
Effects of Overexposure:IRRITATION OF NOSE AND THROAT, SWEATING,
SHORTNESS OF BREATH, WEAKNESS, LOCAL DERMATITISS, NAUSEA, COUGHING,
CHEST PAINS.
Medical Cond Aggravated by Exposure:RESPIRATORY SYSTEM DISORDERS,
PROSTATIC DISORDERS, LIVER AND KIDNEY DISORDERS.

First Aid

First Aid:INHALATION: REMOVE FROM EXPOSURE, SEE PHYSICIAN.
INGESTIOM:INDUCE VOMITING IF CONSCIOUS, SEE PHYSICIAN. SKIN/ EYES:
FLUSH WITH WATER FOR 15 MINUTES. SEE PHYSICIAN IF SYMPTOMS DEVELOP.

Fire Fighting

Extinguishing Media:DRY CHEMICAL, CO2, WATER
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SELF-CONTAINED
BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING IF INVOLVED IN
FIRE.
Unusual Fire/Explosion Hazard:"NOT APPLICABLE"

Accidental Release

Spill Release Procedures:CONTAIN SPILL. COLLECT THE SPILLED MATERIAL
AND PLACE IT IN A PLASTIC-LINED CONTAINER HEPA VACCUMING IS
PREFERRED. FLUSH SPILL AREA WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:WEAR NIOSH/MSHA APPROVED DUST MASKS OR
RESPIRATORS; IMPERVIOUS GLOVES; AND SAFETY GLASSES OR GOGGLES.
Other Precautions:KEEP CONTAINER CLOSED, AVOID CONTACT WITH CLOTHING,
AVOID GENERATING DUST.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED FOR DUSTS
Ventilation:SUFFICIENT TO MAINTAIN OSHA PEL.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:DO NOT WEAR CONTAMINATED CLOTHING HOME.
SHOWER AND CHANGE OR WEAR COVERALLS.
Work Hygienic Practices:KEEP FOOD AND TOBACCO AWAY FROM WORK AREA.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:Z5
Spec Gravity:1.6 (?)
Solubility in Water:FIELD LEFT BLANK
Appearance and Odor:FIELD LEFT BLANK BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:GENERAL STORAGE PROCEDURES FOR HAZARDOUS
MATERIALS ARE ACCEPTABLE.
Hazardous Decomposition Products:METAL OXIDE FUMES MAY BE EVOLVED AT
TEMPERATURES ABOVE MELTING POINT.

Disposal

Waste Disposal Methods:DISPOSE I/A/W ALL FEDERAL, STATE AND LOCAL
REGULATIONS. IF DISCARDED, TREAT AS HAZARDOUS WASTE.

Toxicology

Toxicological Information:NO DATA PROVIDED BY MANUFACTURER.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:NO DATA PROVIDED BY MANUFACTURER.

Transport

Transport Information:NO DATA PROVIDED BY MANUFACTURER

Regulatory

SARA Title III Information:NO DATA PROVIDED BY MANUFACTURER.
Federal Regulatory Information:NO DATA PROVIDED BY MANUFACTURER
State Regulatory Information:NO DATA PROVIDED BY MANUFACTURER